| Isolation Transformer |
|
| |
CEPOWER has a wide range of ISOLATION
TRANSFORMERS which reduce the effects of power Line problems like noise,
spikes, surges, transients and neutral, to a minimum Isolation
Transformer |

 |
| |
Power generation in our country, is no doubt good and availability
of continuous power is Certainly better, but the stringent requirements
of the sophisticated equipment being used today underlines necessity of
clean power. |
| |
Owing to inductive loads, capacitive loads, SMPS loads, electronic
ballasts and with PWM Switching systems, the present AC Power lines are
superimposed with dangerous spikes, Surges, transients, sags and RFI
noise and harmonics. |
| |
As a result failure rates of electronic equipment are on the rise.
Without adequate protection, All electronic equipment is at a great
RISK. Isolation Transformer |
| |
Usually the failures are not seen right away. Repeated stress from
normal electrical transients weaken components and lead to shortening of
component life. Line noises like spikes, surges, transients and so on
definitely cause stress on semi conductor components. And Machine
Systems experience catastrophic program and software failures, extensive
damage to PLC’s and storage media, leading to heavy losses of
production, data and man-hours. |
| |
Usually the failures are not seen right away. Repeated stress from
normal electrical transients weaken components and lead to shortening of
component life. Line noises like spikes, surges, transients and so on
definitely cause stress on semi conductor components. And Machine
Systems experience catastrophic program and software failures, extensive
damage to PLC’s and storage media, leading to heavy losses of
production, data and man-hours. |
| |
With Zodiac ISOLATION TRANSFORMERS all types of electrical noises,
particularly common mode noises, spikes, surges, and transients can be
eliminated. Isolation Transformer |
| |
|
| |
|
| |
TECHNICAL INFORMATION |
| |
|
| |
|
| |
MODELS |
| |
|
| |
|
| INPUT |
OUTPUT |
RATINGS AVAILABLE |
| 415V AC 3-Ph |
415 V AC 3-Ph |
150VA 3-Ph and up to 500 KVA 3-Ph |
| 415V AC 3-Ph |
220 V AC 3-Ph |
150VA 3-Ph and up to 500 KVA 3-Ph |
| 230 V AC 1-Ph |
230 V AC 3-Ph |
150VA 1-Ph and up to 50 KVA 1-Ph |
| 230 V AC 1-Ph |
110 V AC 3-Ph |
150VA 1-Ph and up to 50 KVA 1-Ph |
|
| |
|
| |
SPECIFICATIONS |
| |
|
| System Connections
|
Delta / star or Star
/ Delta |
| Ratios |
1:1 and 2:1 |
| Regulation |
Better than 3.5 % |
| Power Factor |
0.75 lag to 0.75 lead |
| Di-electric strength |
2500 V AC for 120 Sec |
| Insulation resistance |
More than 1000 Mega Ohms |
| Coupling Capacitance |
0.1 PF for 100 db |
| Leakage Current |
Less than 20 micro amps |
| Common Model attenuation |
100 db |
| Construction Standards |
As per IS 2026 part 1 &11 |
|
| |
|
| |
APPLICATIONS |
| |
|
| • |
CNC Machines |
| • |
Bio Medical Equipment |
| • |
Printing Machinery |
| • |
Large Computer Installations |
| • |
Telecommunication Equipment |
| • |
Scientific Equipment |
| |
|
|